General-Purpose Series (SF/SB type)
Back to Product Lineup

Specifications
 
Standard type model Heat-resistance type model
Impeller Model Outlet flange diameter (mm) Phase Output (kW) 50Hz 60Hz Highest intake temperature Highest intake temperature
Revolutions (min-1) Max air flow (m3/min) Max static pressure (KPa) Revolutions (min-1) Max air flow (m3/min) Max static pressure (KPa)
Sirocco SF-38 41 single 0.025 2830 1.1 0.21 3280 1.2 0.31 40°C 180°C
SF-50 49 single 0.04 2700 2.2 0.32 3200 2.6 0.45 40°C 180°C
SF-55S 49 single 0.04 2700 2.5 0.31 3200 2.8 0.44 40°C 180°C
SF-75 75 single 0.25 2800 8.0 0.55 3400 9.5 0.80 40°C 200°C
SB-75 75 3 0.25 2800 8.0 0.55 3400 9.5 0.80 40°C 200°C
Turbo SB-151 41 single 0.04 2700 1.6 0.47 3200 2.0 0.66 40°C X
SB-201 49 single 0.04 2700 2.2 0.47 3200 2.6 0.66 40°C 200°C
SB-202 49 3 0.04 2700 2.2 0.47 3200 2.6 0.66 40°C 200°C
The number in ( ) indicates overrated max. airflow.
SF/SB type In the general purpose series, there are Sirocco(SF) and Turbo(SB) types.
Please choose size and performance to suit. SB-151, 201, 202 are the best sellers.
Following model changes to fully enclosed type for ease of use.
Caution:If the intake temperature is above 40°C, please use the heat-resistant
type model (HT model).

Purposes
 
  • Printing machines
  • Incinerators
  • Packing machinery
  • Driers
  • Burners
  • Hot blast generating machines
  • Laundry machinery
  • Heating cabinets
  • Stain removing machinery
  • Confectionery machines
  • General ventilation